Customization: | Available |
---|---|
Remote Control: | Without Remote Control |
Load Type: | Direct |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATION
Power source: 220-240V/A C
Power Frequency: 50/60Hz
Rated Current: 10A
Ambient Light: <10-45LUX
Working Temperature: -20~+40ºC
Working Humidity: <93%RH
INSTALLATION
Switch off the power. Unload the black bottom from the white roof directly.
Unscrew two nails in the black bottom and unload into two parts.
Pass the wire through the hole in the bottom and connect the power according to the connection-wire diagram.
Install back the two nails and according to the correct installation place install the item with the enclosed inflated screws.
Install back the white roof onto the black bottom. Turn on the power and then test it.
TEST
Switch on the power.
When you test in daytime. You should cover a black opaque cloth on the product.
When the cloth mantles the detection window of the photocell, the ambient light of the photocell is dark, the lamp will be on.
When you take off this cloth, the lamp will be off automatically.
NOTE
In front of the photocell, it should be no obstruction affecting to accept natural light;
In front of the photocell, it should be no swaying object.
Don't install the photocell under the light or in the place where the light will be irradiated to the photocell.