• Bx-Dt004 with Defrost Function Digital Display Temperature Controller
  • Bx-Dt004 with Defrost Function Digital Display Temperature Controller
  • Bx-Dt004 with Defrost Function Digital Display Temperature Controller
  • Bx-Dt004 with Defrost Function Digital Display Temperature Controller
  • Bx-Dt004 with Defrost Function Digital Display Temperature Controller
  • Bx-Dt004 with Defrost Function Digital Display Temperature Controller

Bx-Dt004 with Defrost Function Digital Display Temperature Controller

Customized: Customized
Certification: RoHS, CCC, ISO9001, CE
Brand: Bxst
Display Type: LED
Model No: Bx-Dt002
Uantity Per Carton: 120PCS/Carton
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
BX-DT004
G.W
27.5 Kgs/Carton
Transport Package
Color Box
Specification
520*505*347mm/Carton
Trademark
BXST
Origin
Wenzhou, China
Production Capacity
10000

Product Description

BX-DT004 Microcomputer temperature controller operating instructions
  • Name of commodity: Digital display temperature controller
  • Product features:BX-DT004 type main digital display temperature controller is a common sensor temperature controller, refrigeration, defrosting, temperature overrun alarm function.compressor protection time delay curing For 3 minutes,After the sensor fault In accordance with the curing proportion Switch machine.
  •  Scope of application:Suitable for cold storage, refrigerated truck refrigeration industry, etc
Main function
Temperature measurement, display and control
Defrost cycles and defrosting time can be adjusted
Temperatures exceed limit alarm
Compressor boot protection
temperature sensor failure proportion Switch machine

Size
★Panel size:75*34mm (L*W)
★Installation hole size:71*29mm(L*W)
★Overall size:75*34*66.5mm(L*W*H)
★Temperature sensor length:2M

Technical parameters
Working voltage:AC220V+10%/-15%,50~60Hz
Power consumption of the machine:≤3W
Measuring range:-50ºC~99ºC

Control range:-40ºC~50ºC
Accuracy of measurement:-40ºC~50ºC,±1ºC,other ±2ºC
Temperature resolution:1ºC
Refrigerating output contacts capacity:10A/220VAC
Defrost output contacts capacity:10A/220VAC
Sensor fault latency:1minutes
Sensor type:NTC Sensor
front panel protection grade:IP64
Working environment temperature:0ºC~60ºC
Work environment humidity:20~85%(No condensation)
Storage temperature:-30ºC~75ºC

PanelBx-Dt004 with Defrost Function Digital Display Temperature Controller
Button function Display mode
short Click up Button Highest temperature display Settings
short Click down button Lowest temperature display Settings
short Click set button Display of defrost cycle
short Click Rst button Display the defrosting time

Modify the parameters set value
Press set key more than 3 seconds to enter parameters change model, shows that after electrify the last adjustment menu item,At the same time parameter modify mode indicator.

Press the up or down keys can be move up or down menu item;The parameter setting of the press Set key displays the current menu.

Press Set key, then press the up or down keys to adjust the current menu parameters Set value;At the same time hold the Set key and the up key for more than 1 second can be quickly raised the parameters setting of the current menu;At the same time hold the Set key and key down for more than 1 second parameter value can be quickly cut the current menu.

Press Rst or 30 seconds without any key operation, save parameter changes and return to normal temperature display status.

★Manual defrost
○Defrosting time not is set to 0,  allow manual defrost
○do not defrosting hold the button down for 3 seconds when the above can manually open defrosting
○Defrost hold the button down for 3 seconds when the above can be stopped manually defrosting
★Recovery parameter Settings
○machine up electricity, you check the parameter setting is correct.If the check to the error, the display E1, at the same time a buzzer sounded.Press Set key at this time will restore the default parameter Settings and work normally, suggest to reset parameters at this time.
 
Button feature list
 
Button name Normal mode Modified Parameters
Press and release the Set key View the defrost cycle view parameters setting of the current menu
Press set key for 3 seconds Enter the parameter modification  
Press and release the Rst key View the defrosting time Exit the parameter modification
Press and release up key View the highest temperature limit menu up
Press and release down key view the minimum temperature limits menu down
Press set key for 3 seconds Manual defrost  
Hold press set key,press up key   Increasing parameter
Hold press set key,press down key   Parameters of diminishing

Output control

Compressor:
Library temperature higher than the set limit on the temperature of the compressor open, lower than the set time limit under the temperature of compressor shut down.Library temperature sensor fault compressor according to the open 15 minutes after the proportion of 30 minutes, stop running.Machine or compressor shut down after running 3 minutes after the power supply of compressor protection time to allow the compressor to open again.

Defrost:
Machine run Settings or defrost defrost cycle more than hold down the button for 3 seconds defrosting, defrosting is prohibited during the refrigeration output.Depleted or defrosting defrosting time hold down the button more than 3 seconds defrosting end.Machine electricity or thawed after re-run the defrost cycle.Defrost cycle or any of the defrosting time is set to 0 to eliminate timing defrost function, but when to allow manual defrost defrost time is not zero.

warning:
Temperature overrun deviation is not 0, the library temperature higher than the set temperature limit + deviation or below the set temperature overrun occurs when the temperature of the lower limit temperature overrun deviation transfinite alarm temperature, the flashing display the current temperature and the buzzer sounded.Cancel the alarm temperature back to normal after the temperature range.
Storage failure flashing display E1 and the buzzer rang;Sensor fault show flashing E2 and buzzer ringing;Temperature higher than 99 ºC and below 120 ºC show HH.Alarm when press any key to manually, but does not change the state of alarm display.

Indicator light state
Indicator light Indicator light state Function
Defr Long bright Defrost the output
Cool Long brightD ompressor output
Cool Flashing Compressor output delay
Set Long bright Parameters Modify

★Menu description

Menu description Menu features Set range Unit Default value
F1 Temperature Max F2~+50 ºC -10
F2 Temperature Min -40~F1 ºC -20
F3 Temperature calibration -5~+5 ºC 0
F4 Defrost cycle 0~99,set 0 cancel timing defrost Hours 8
F5 Defrost time 0~99,set 0 cancel timing defrost Minutes 20
F6 Temperature Ultra limit deviation 0~50,set 0 cancel warning ºC 15

Safety rules

○dangerous

1.Strictly distinguish between the sensing lines, power cord, and the output relay interface, can not be wrong, relay always over load

2.All wiring changes must be conducted under the condition of the power off
○warning

 This machine is prohibited in the water or damp environment use, banned in high temperature, strong electromagnetic interference, strong corrosive environment;

○Pay attention to

1.The power supply voltage should be consistent with the voltage marked on the machine, and ensure the stability of the power supply voltage

2.To avoid possible interference, it is recommended that the sensor lead keep proper distance with power lines

wiring diagram  
Bx-Dt004 with Defrost Function Digital Display Temperature Controller

Fault code, reason and action

 

Fault code Cause of the problem Action
E1 Memory fault Alarm, the machine does not work
E2 Temperature sensor failure Alarm,   compressor proportion switch
HH Temperature is beyond the scope display ---
Contact us know more products!
Bx-Dt004 with Defrost Function Digital Display Temperature Controller


Bx-Dt004 with Defrost Function Digital Display Temperature Controller
Bx-Dt004 with Defrost Function Digital Display Temperature Controller
Bx-Dt004 with Defrost Function Digital Display Temperature Controller
Q:Are you a factory?
A:Yes,we are a factory which has been focusing on research and development and manufacturing all kinds of socket for 10 years.  

Q:What if there is some problems with your products after I receive the bulk?
A:The rate of our qualified products is 99%-100%.If some products are not working when you receive them,we will supply you the same quantity qualified products.

Q:What is the material of your products?
A:  The shell material is ABS, PC, PA66, V0 Flame-retardant level. Hardware is 0.7 mm thick of beryllium bronze. Our company uses relay with high quality which is bought from Sky-Wave and Loose Joy. All chips are imported from Taiwan and United States.
 
Q:How can I get some samples?
A:All the sample is available in stock, we can send you free sample if you can pay the express fee.
 
Q:How does your factory do regarding quality control?
A:We have professional QC department, we inspect all steps from the purchase of the materials to the departures of products from our factory according to the standard test. We always attach great importance on quality control from the beginning to the end . Our factory has gained CE.FCC.Rohs ceritificate.
 
Q:When you ship my order?
A:Normally 30to45days after receiving your payment,but it can be negotiated based on production schedule.
 
Q: How long is the product warrenty period?
A:Every products has the patent of the original, we promise that the products have two year warrenty, but the counterfeit products are not included in the warrenty period
 
Q: How to identify the quality goods is BXST?
A:We all have anti-counterfeiting qr code on each PCB circuit boards

If you want to know more, please contact us, we will get back to you as soon as possible!
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now